View article: Lens shape confirmed in light adjustable lens: A report of two cases
Lens shape confirmed in light adjustable lens: A report of two cases Open
The findings in Case 1 highlighted a change in shape while maintaining a spherical lens shape, while in Case 2, the change in asymmetric shape may have occurred to correct astigmatism on the back of the LAL. Taken together, these findings …
View article: Evaluation of the Insertion Depth of the iStent Inject W and Its Association with Surgical Outcomes Using Automated Gonioscopy
Evaluation of the Insertion Depth of the iStent Inject W and Its Association with Surgical Outcomes Using Automated Gonioscopy Open
Background/Objectives: The iStent is a trabecular micro-bypass device used in glaucoma management. Its depth has been evaluated using anterior segment optical coherence tomography; however, no reports have assessed it using gonioscopy. We …
View article: Study on Factors Affecting Toric Intraocular Lens Rotation Using Intraoperative OCT—Factors Influencing IOL Deployment and Proximity to Posterior Capsule After Insertion
Study on Factors Affecting Toric Intraocular Lens Rotation Using Intraoperative OCT—Factors Influencing IOL Deployment and Proximity to Posterior Capsule After Insertion Open
Background/Objectives: Cataract surgery often reveals preexisting corneal astigmatism, which can be corrected using a toric intraocular lens (T-IOL). However, postoperative T-IOL rotation may compromise correction. We investigated T-IOL ro…
View article: Comparison of angle-closure detection between automated gonioscopy and anterior-segment optical coherence tomography
Comparison of angle-closure detection between automated gonioscopy and anterior-segment optical coherence tomography Open
Purpose To investigate the concordance between angle-closure assessments based on GS-1 gonioscope images and those obtained with anterior-segment optical coherence tomography. Study design Retrospective clinical study . Methods We included…
View article: Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2) Open
Purpose The IMOvifa™ perimeter with a 24plus (1-2) testing mode has additional measurement points within the central 10 degrees, which may help evaluate the visual field within this area. Here, we comparatively evaluated the IMOvifa™ 24plu…
View article: Comparison of IMO vifa24plus(1-2) and Humphrey Field Analyzer 24-2
Comparison of IMO vifa24plus(1-2) and Humphrey Field Analyzer 24-2 Open
The IMO vifa demonstrates a very high correlation with HFA and allows for a shorter examination time. Fixation errors are significantly improved compared to HFA, while there is no significant difference in false positives or false negative…
View article: Comparison of accuracy and axial length acquisition success rate by three types of swept-source OCT-based biometers
Comparison of accuracy and axial length acquisition success rate by three types of swept-source OCT-based biometers Open
Purpose: To compare three biometers equipped with swept-source optical coherence tomography (OCT), including ARGOS (OCTB1), IOLMaster 700 (OCTB2), and Anterion (AS-OCTB). The primary aim was to assess the axial length (AL) acquisition succ…
View article: Comparison of the efficacy and invasiveness of manual and automated gonioscopy
Comparison of the efficacy and invasiveness of manual and automated gonioscopy Open
Purpose To compare the efficacy and invasiveness of manual gonioscopy and automated 360-degree gonioscopy. Method Manual and automated gonioscopy were performed on 70 patients with glaucoma. Manual gonioscopy was performed by a glaucoma sp…
View article: Refractive Errors after Cataract Surgery Using Total Keratometry in Post-LASIK Eyes
Refractive Errors after Cataract Surgery Using Total Keratometry in Post-LASIK Eyes Open
【目的】LASIK後眼に対しTotal Keratometry(TK)を用いたLASIK用IOL度数計算式と従来式による予測屈折誤差を比較し、TKの有用性を評価する。
View article: Comparison of Postoperative Outcomes of Trifocal Intraocular Lens with Enhanced Depth of Field and Diffractive Bifocal Intraocular Lens
Comparison of Postoperative Outcomes of Trifocal Intraocular Lens with Enhanced Depth of Field and Diffractive Bifocal Intraocular Lens Open
【目的】眼内レンズ(以下IOL)面で1.5Dと3.0Dの加入がある焦点深度拡張3焦点IOL AcrivaUD Reviol Tri-ED611 611T(VSY Biotechnology社)と、IOL面で2.5D加入がある2焦点IOL SV25Tx(Alcon社)の術後成績を比較した。
View article: Comparison of Astigmatism Correction Effect Between Toric Intraocular Lenses Determined by Optical Biometric Device and Anterior Segment Optical Coherence Tomography
Comparison of Astigmatism Correction Effect Between Toric Intraocular Lenses Determined by Optical Biometric Device and Anterior Segment Optical Coherence Tomography Open
【目的】前眼部OCTの角膜前後面実測値(Real)とIOLMaster®700のTotal Keratometry(以下TK)によるトーリック眼内レンズ(以下T-IOL)の乱視矯正効果の比較。
View article: Clinical and ex vivo laboratory comparison of the self‐sealing properties and dimensional stability between the femtosecond laser and manual clear corneal incisions
Clinical and ex vivo laboratory comparison of the self‐sealing properties and dimensional stability between the femtosecond laser and manual clear corneal incisions Open
Purpose To compare the self‐sealing features and dimensional stability between the femtosecond laser ( FL ) and manual knife corneal incision. Methods For the clinical study, 29 consecutive eyes from 29 patients and 28 eyes from 28 patient…